Common array manager.

This document describes a possible problem in Sun Storage Common Array Manager (CAM) version 6.9.0.20 on Solaris that can prevent registration of arrays. CAM 6.9.0.20 involves the installation of CAM 6.9 and then the addition of either <Patch 147416-02> (Solaris SPARC) or <Patch 147419-02> (Solaris x86). Array registration in …

Common array manager. Things To Know About Common array manager.

The Sun Storage Common Array Manager CLI Guide, Version 6.9.0, describes the commands in the sscs command-line interface (CLI) for Oracle's storage arrays. Review the latest array baseline firmware versions delivered with Oracle's Sun Storage Common …vi Sun StorageTek Common Array Manager User Guide for the J4000 Array Family • August 2008 The Event Life-Cycle 67 Setting Up Notification for Fault Management 68 Configuring Array Health Monitoring 76 To Configure the FMS Agent 76 To Enable Health Monitoring for an Array 78 Monitoring Alarms and Events 80Sun Storage Common Array Manager Software Release Notes, Release 6.9.0 Update December 2012. Review important late-breaking information about Sun Storage Common Array Manager.From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays.

The purpose of this document is to describe how to collect logs and configuration data from the machine running Sun Storage Common Array Manager version 6.0 or later. The command will collect the configuration database and all relevant log files for support and troubleshooting. If you need to collect a support data from the array, please …Sun Storage Common Array Manager (CAM) - Version 6.1 to 6.10 [Release 6.0]: Sun Storage Common Array Manager (CAM): Connections Refused with Error "ERR_SSL_WEAK_SERSun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports.

Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.8.1. 2 2510_exmoor N1532-735843-002 nge/N1532-735843-002.dlp

Common Array Manager. user-lvozg Feb 12 2023. Unable to see StorageTek6410 in Oracle Java Web Console after installing Common Array Manager, but I can only see Hosts statistics such as cpu usage, local hard drive and memory usage status.Look for the StorageTek Common Array Manager (CAM) Software release 6.1.2 or later. Using CAM With Disk Blades and Virtualized Multi-Fabric 10GbE NEM. CAM provides both a browser and command-line interface. When using the browser interface, you set up user accounts. When an authorized user logs in, information is laid out in pages.The Program calculates the sets, rises and phases of the sun and moon... The HPE Smart Storage Administrator (HPE SSA) is a web-based application... Trusted Windows (PC) download Sun Storage Common Array Manager Online Help 6.9.0.16. Virus-free and 100% clean download.Setting Up Notification for Fault Management. The fault management features of Sun Storage Common Array Manager enables you to monitor and diagnose your arrays and storage environment. Alarm notification can be provided by: Email notification Simple Network Management Protocol (SNMP) traps1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …

Instructions to download Common Array Manager (CAM). Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download. Click on "Search".

To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage; guest; User names must be a currently defined user on the management host.

The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …Common Array Manager May be Solaris forum is not the best choice for asking such question, but I really need help with SunStorage FC array. AFAIK this array can be configured only with CAM software by Sun, but sadly all previously free Metalink downloads are now accessible only as a part of paid support (and I have no idea why we …Support data for an array is collected and saved in the Common Array Manager by selecting array > General Configuration > Support Data. On the Windows 2008 server, disable “Do not save encrypted pages to disk.” Go to Tools > Internet Options > Advanced > Security and uncheck "Do not save encrypted pages to disk." Linux platforms1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet n.n.n.n. 3. After logging in, switch user …

Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application.Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and …Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Mar 9, 2022 · Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application. Common Array Manager alarm code xx.66.1091: Battery Tray.xx.Battery.x has transitioned to an unknown state; SANtricity Storage Manager fault of BATTERY_UNKNOWN_STAT; Reference: <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, …This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support …

The Sun StorageTek Common Array Manager CLI Guide describes the commands in the sscsCLI. Consult the hardware installation guide for your array for information about the initial physical installation of an array. Related Documentation In addition, the Sun StorageTek Common Array Manager includes the following online documentation:

See your Sun StorageTek Common Array Manager Software Installation Guide (part number 820-4193) or Sun StorageTek Common Array Manager User Guide for the J4000 Array Family (part number 820-3765). 5. Log in as root (Solaris and Linux) or as a user with administrator privilege (Windows) on the management host. 6.Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Purpose. The purpose of this document is to help troubleshoot the Sun Storage Common Array Manager (CAM) login problem that produces the error:This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of …iv Sun StorageTek Common Array Manager CLI Guide • April 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 29 Examples 30 Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.8.1. 2 2510_exmoor N1532-735843-002 nge/N1532-735843-002.dlp Performing Connection and Administration Tasks 36 Connection Tasks 37 Managing From the Site LAN 37 Managing an Array Isolated From the LAN 38 1 Sun StorageTek Array Administration Guide • March 2007 Installing the Remote CLI Client 38 About Host Bus Adapters 39 About Multipathing 39 General Administration Tasks 40 Accessing, Adding, …Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI). The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ...

The Sun StorageTek [TM] Common Array Manager (CAM) has the ability to collect support based configuration and logs for Sun StorEdge [TM], Sun StorageTek [TM], StorageTek …

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …

This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Sun Storage Common Array Manager. Quick Start Guide. 2. Download Sun Storage Common Array Manager Software and Patches. 1. Sign in to My Oracle Support: …Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, …Apr 3, 2023 · Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. This can be performed using the Browser or CLI interface. The purpose of this document is to describe how to collect this information. If you are using a Sun Storage J4000 ... Storage Common Array Manager 6.10 Update. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 …The Sun StorageTek Common Array Manager (CAM) software suite is your main tool for Sun Storage array enclosure management, monitoring, and service capabilities. The software has both a secure browser interface and a command-line interface (CLI). CAM is supported for use with Solaris, Linux and Windows platforms. Viewing Sun Storage …The Sun Storage Common Array Manager (CAM) 6.10 release is available only for Solaris OS management hosts. CAM 6.10 for Linux and Windows hosts is in development and will be available once it is complete. Until then, continue to use CAM 6.9 for Linux and Windows, which is available from My Oracle Support (MOS) https://support.oracle.com.1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …Common Array Manager May be Solaris forum is not the best choice for asking such question, but I really need help with SunStorage FC array. AFAIK this array can be configured only with CAM software by Sun, but sadly all previously free Metalink downloads are now accessible only as a part of paid support (and I have no idea why we …

Mar 9, 2022 · Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application. 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Sun Storage 2530-M2 Array - Version Not Applicable and later All Platforms Goal. This document describes the significance of a volume's "owning controller" and "preferred controller", and also explains how to change the "owning controller" setting of an individual volume via the Sun Storage Common Array Manager software.This article documents Sun Storage 6580/6780 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Instagram:https://instagram. yuka foodflights from seattle to san francisco californianatural gas njsign in pandora internet radio 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - mechanical licensing collectiveboston to athens flights This document describes a possible problem in Sun Storage Common Array Manager (CAM) version 6.9.0.20 on Solaris that can prevent registration of arrays. CAM 6.9.0.20 involves the installation of CAM 6.9 and then the addition of either <Patch 147416-02> (Solaris SPARC) or <Patch 147419-02> (Solaris x86). Array registration in … jeopardy template ppt Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are …The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is …